Search results for "Treatment Planning System"

showing 3 items of 3 documents

EPR/alanine dosimetry for two therapeutic proton beams

2016

Abstract In this work the analysis of the electron paramagnetic resonance (EPR) response of alanine pellets exposed to two different clinical proton beams employed for radiotherapy is performed. One beam is characterized by a passive delivery technique and is dedicated to the eyes treatment (OPTIS2 beam line). Alanine pellets were irradiated with a 70 MeV proton beam corresponding to 35 mm range in eye tissue. We investigated how collimators with different sizes and shape used to conform the dose to the planned target volume influence the delivered dose. For this purpose we performed measurements with varying the collimator size (Output Factor) and the results were compared with those obtai…

Nuclear and High Energy PhysicsDosimeterProtonChemistrySettore FIS/01 - Fisica SperimentaleSobpCollimatorSettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)030218 nuclear medicine & medical imaginglaw.invention03 medical and health sciences0302 clinical medicineNuclear magnetic resonancePlanned Doselaw030220 oncology & carcinogenesisProton beam Alanine ESR EPR Treatment Planning System PSIPLAN SOBPDosimetryIrradiationInstrumentationBeam (structure)
researchProduct

Implementation of advanced methodologies in the commissioning of a Light Ion Beam Therapy facility

Particle TherapyMedical CommissioningTreatment Planning SystemProtonParticle Therapy; Protons; Alanine dosimetry; Monte Carlo; Medical Commissioning; Treatment Planning SystemAlanine dosimetryMonte CarloSettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)
researchProduct

12C ion beam dose distribution in presence of medium inhomogeneities: comparison between different measurements and simulations with the treatment pl…

2012

Heavy-ions beams offer several advantages compared to other radiation such as low lateral scattering and high biological effectiveness (RBE) in the Bragg peak region, making them particularly attractive for the treatment of radio-resistant tumours localized close to organs at risk [1]. The extension of ion therapy to new clinical cases requires the exploitation of a dedicated treatment planning system (TPS) based on the existing version of TRiP98 [2,3], established TPS for carbon ions. The theoretical models and experimental databases included in TRiP98 are presently mainly based on measurements in water. This approximation can be applied successfully to reproduce many biological tissues wi…

ion therapyESR and TL dosimetry for treatment planning systemSettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)
researchProduct